Original Article

A-Mode Ultrasound in the Diagnosis of Maxillary Sinusitis in Ventilated Patients

Volume 6 · Issue 3 Publish Date: September 15, 2010
Full Text PDF
S. Boet
Department of Anaesthesia and Intensive Care; University Hospital of Rouen, 1 rue de Germont, 76000 Rouen, France
B. Guene
Department of Anaesthesia and Intensive Care; University Hospital of Rouen, 1 rue de Germont, 76000 Rouen, France
D. Jusserand
Department of Anaesthesia and Intensive Care; University Hospital of Rouen, 1 rue de Germont, 76000 Rouen, France
B. Veber
Department of Anaesthesia and Intensive Care; University Hospital of Rouen, 1 rue de Germont, 76000 Rouen, France
J.-N. Dacher
Department of Radiology; University Hospital of Rouen, 1 rue de Germont, 76000 Rouen, France
B. Dureuil
Department of Anaesthesia and Intensive Care; University Hospital of Rouen, 1 rue de Germont, 76000 Rouen, France
Boet, S., Guene, B., Jusserand, D., Veber, B., Dacher, J.-N., & Dureuil, B. (2010). A-Mode Ultrasound in the Diagnosis of Maxillary Sinusitis in Ventilated Patients. B-ENT, 6(3), 177–182. Retrieved from https://www.b-ent.be/index.php/pub/article/view/319
Full Text Full Text PDF

Abstract

A-Mode Ultrasound in the Diagnosis of Maxillary Sinusitis in Ventilated Patients. Problems/objectives: The diagnosis of maxillary sinusitis in intensive care patients remains problematic. However, it is essential since maxillary sinusitis causes numerous complications and there is an effective treatment. The aim of this study was to compare A-mode ultrasound with sinus computed tomography (CT) for the diagnosis of maxillary sinusitis in intubated patients in critical care undergoing mechanical ventilation. Methodology: Prospective clinical study in 140 maxillary sinuses in the surgical ICU of a university hospital. In each intubated and mechanically ventilated patient undergoing cerebral CT scan for any reason, a bedside A-mode ultrasonography of the maxillary sinuses was performed the same day. The A-mode ultrasound result was compared with the result of the sinus CT scan for the diagnosis of maxillary sinusitis. Results: Sensitivity, specificity, positive predictive value and negative predictive value of A-mode ultrasound compared with CT were 66.7%, 94.7%, 75.0% and 92.2% respectively. All the empty sinuses were correctly identified as being empty. Conclusions: Given its very good specificity and negative predictive value, bedside A-mode ultrasound may be a useful first-line examination for intubated and mechanically ventilated patients in intensive care, especially to eliminate suspicion of maxillary sinusitis.

Similar Articles

Article Info
Published In
Journal B-ENT
Volume / Issue Volume 6 · Issue 3
Pages 177-182
History
Published Online September 15, 2010
Affiliations
S. Boet
Department of Anaesthesia and Intensive Care; University Hospital of Rouen, 1 rue de Germont, 76000 Rouen, France
B. Guene
Department of Anaesthesia and Intensive Care; University Hospital of Rouen, 1 rue de Germont, 76000 Rouen, France
D. Jusserand
Department of Anaesthesia and Intensive Care; University Hospital of Rouen, 1 rue de Germont, 76000 Rouen, France
B. Veber
Department of Anaesthesia and Intensive Care; University Hospital of Rouen, 1 rue de Germont, 76000 Rouen, France
J.-N. Dacher
Department of Radiology; University Hospital of Rouen, 1 rue de Germont, 76000 Rouen, France
B. Dureuil
Department of Anaesthesia and Intensive Care; University Hospital of Rouen, 1 rue de Germont, 76000 Rouen, France
Cite this Article
Boet, S., Guene, B., Jusserand, D., Veber, B., Dacher, J.-N., & Dureuil, B. (2010). A-Mode Ultrasound in the Diagnosis of Maxillary Sinusitis in Ventilated Patients. B-ENT, 6(3), 177–182. Retrieved from https://www.b-ent.be/index.php/pub/article/view/319
Outlines